Model TS-16V
Transducer Simulator
 
TS-16V Transducer Simulator

SPECIFICATIONS

Download Manual in PDF Format
Impedance: 350 ohms nominal
Output Ranges:
Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
10 turn vernier with locking graduated dial
OFF: Rotary selection + 0.0 mv/v
FINE: Rotary selection - 0.01 mv/v to +0.2 mv/v
MEDIUM: Rotary selection - 0.04 mv/v to +1.0 mv/v
COARSE: Rotary selection - 0.08 mv/v to +30 mv/v
Note: Vernier ranges may vary from above
Output Accuracy:
Typically Max
+ 0.008% + 0.020% of full scale
+ 0.00024 mv/v + 0.00060 mv/v
or +1 microvolt, whichever is greater
Zero Offset:
Typically Max
+ 0.00009 mv/v + 0.0005 mv/v
or +1 microvolt, whichever is greater
Temp. Coefficient: + 5 ppm/°C
Excitation: 20v ac/dc max
Termination: Binding posts - accepts standard banana plug or up to No. 14 wire
Weight: 1Lbs.
Dimensions: 5.9"L x 3.2"W x 2.9"D
Enclosure: ABS Thermoplastic Case

Key Benefits

[Bullet] Made In USA
[Bullet] Highest Quality Components
[Bullet] 100% Tested
  • Call for OEM & Quantity Pricing
  • Custom Build Available

We manufacture and distribute a complete line of products for the scale industry.
Contact us and we can help you build your own Platform Scale, Tank Scale, or Batching System.
Home
Transducer Simulators
MODEL 0V MODEL 6 MODEL 7 MODEL 7V TS-16 TS-16V 
sales@controlweigh.com
CONTROLWEIGH
847-540-8260
Fax: 847-540-8270

 

 

Copyright © 1989-2022 CONTROLWEIGH